The short answer
Switch off the part that can do harm when an AI workflow takes an unapproved external action, crosses a data boundary or meets a stop condition you agreed in advance. Block sends or writes first. Hold the backlog, switch urgent work to a manual queue and tell the person who owns the service. You can read the prompt later.
A useful stop condition can be recognised on a busy shift. “The AI is behaving oddly” gives people room to wait for a second opinion while the next jobs run. “One unapproved customer message” is a decision. Rate-based thresholds can make sense for lower-impact failures, but only if someone knows the denominator, the observation window and what to do while a suspected error is checked.
Know what the switch actually stops
Find the control nearest the external effect. Disabling a form may stop new submissions while the worker drains its existing queue. Suspending the scheduler may leave callbacks and retries alive. Map where pending work sits and which routes can still write to the destination. If a narrowly scoped pause cannot be verified, stop the whole workflow rather than assume it’s isolated.
Make the control usable by a named shift role and backup. Check that both have access before launch. Have the on-call person run the exercise instead of asking the engineer who built it to show how it works. If the stop takes three tools and a permission request, that’s information you need before the first incident. The NIST AI Risk Management Framework Manage playbook discusses contingency and deactivation; a stop card is how the team makes those ideas usable in the moment.
Copy this stop, fallback and restart card
| Decision | Fictional fulfilment-update assistant | Fill in for your workflow |
|---|---|---|
| Stop trigger | One unapproved customer send or any cross-account disclosure; also pause after two confirmed material status errors in the last 20 reviewed drafts | [Red lines; error definition; window and denominator] |
| Who can pause | Duty operations lead or service supervisor; no additional approval to pause | [Role, backup and contact route] |
| Stop and verify | Disable customer sends, hold queued jobs and pause retries. Check send audit for activity after the pause. | [Controls, observation and incident record] |
| Manual fallback | Staff read the order system and use the existing update template for urgent items. Log each completion against its original work ID. | [Queue, capacity, owner and priorities] |
| Restart authority | Service owner checks the fix and reconciles the backlog; unresolved data issues go to the incident team | [Authority, evidence and restart criteria] |
The thresholds are fictional. Don’t copy them into a workflow where a single status error is consequential or where nobody reviews 20 drafts. Decide also whether the threshold counts verified incidents, how repeated failures on one item are handled and which symptoms call for a precautionary pause before confirmation.
Suppose the fictional assistant sends an unapproved “dispatched” message. Six updates are queued, and one job is waiting for a retry after a timeout. The duty lead disables automated sends and checks the destination audit. The timeout isn’t proof that the first attempt failed; find out what the customer actually received before sending anything manually. A teammate handles the urgent jobs from the order system, against the original work IDs. The rest stay held. If the cause suggests a cross-account disclosure, the lead follows the incident process rather than attempting to tidy the evidence first.
Restart against the real backlog
Before reopening the write path, reproduce the failure safely and show that the fix blocks it. Run an ordinary case too; correcting one bad path can break the fallback or a legitimate send. Check held and retried items against manual completions and confirm which drafts are stale. Release a small reviewed batch and name the person who’ll watch it. If the stop condition recurs, return to fallback.
Keep pause and restart authority distinct. A shift lead should be able to contain the problem without a committee. The person reopening the workflow needs evidence of the cause, the fix, the backlog reconciliation and what’s still unknown. If there’s no one available to review, the safer plan is to keep the write path paused and report the capacity limit rather than turn it back on to clear the queue.
Practise with a queued item, an in-flight attempt and a manual completion before going live. Try a case with no clean rollback. A CRM merge is a useful example: the CRM data-cleaning guide explains why stopping future writes does not restore a record that’s already merged.
Test what happens if the manual queue runs at half the automated rate. Define what gets done first, who communicates delays and where unfinished items wait. In the fulfilment example, an order at risk of missing a courier cut-off might take priority over a routine confirmation. Put that choice on the card. If the fallback team can clear only 20 items a day, don’t reopen the system just to mask the resulting queue. Conversely, a large queue is not a reason to block safe read-only work if the outbound path is demonstrably isolated. Keep the incoming, completed and held counts visible so the owner can plan a staged recovery.
Frequently asked questions
Open a question to read the full answer.
Do I need to switch off the whole AI workflow?
Only if you can’t verify that the affected write or send path is isolated. A read-only queue may be safe to keep for diagnosis or manual review, but check that it can’t trigger any downstream effect. When there’s uncertainty about a shared worker, callback or credential, pause more broadly until you can prove the narrower boundary.
What if it’s unclear whether an external action already happened?
Stop further attempts and check the destination or the authoritative activity record. A timeout, a blank result or an absent local success log isn’t proof that nothing happened. Don’t replay the job until you know whether the first attempt took effect. If it still can’t be verified, route it to the service owner for a controlled decision.
Who should be able to stop and restart the workflow?
A named duty role and backup should be able to pause it without waiting for a long approval chain. Give restart to the service owner or an authorised delegate who can review the fix and backlog. Document both roles and practise the handover. Someone fixing the issue shouldn’t need to guess whether they’re also authorised to reopen it.
Is there a standard error threshold for switching off?
No. Base it on what the workflow can do, what a mistake costs and how much you can review. A single unapproved external action may justify an immediate stop. For repeatedly reviewed drafts, a rate can work if it has a clear definition and denominator. Test the boundary in a drill so the shift team knows when to use it.
How do we deal with queued work after a pause?
Separate completed, attempted, held and manually finished work. Match each item by its original work ID, not by a similar-looking name or time. Remove stale work from the release plan and check whether a queued retry could bypass it. Reopen in small batches only once the owner can explain what’s left and why each item is safe to run.
Next step
Explore AI for Business if you want to rehearse a pause and restart before your workflow goes live.
Put this into practice
Use the editable worksheet
Take the decision you’re facing, put an owner against it and record what would change your mind. The download is an editable CSV with no signup.
